Reliable Fire Pump Systems for Critical Fire Protection
AA2000 provides professional installation and maintenance of fire pump systems across the Philippines. Ensuring reliable water supply for sprinkler and standpipe systems in high-rise buildings, industrial facilities, and commercial complexes.
Fire Pump Systems & Components
Comprehensive range of fire pumps, jockey pumps, and control systems designed to meet Philippines fire code requirements and international standards.
Electric Fire Pump
High-performance electric-driven centrifugal fire pumps for reliable fire protection. Available in various capacities from 250 GPM to 5000 GPM with pressures up to 300 PSI.
- • Cast iron volute construction
- • Bronze fitted impeller
- • Mechanical seal design
- • TEFC motor enclosure
Diesel Fire Pump
Reliable diesel engine-driven fire pumps for locations with unreliable power supply. Ideal for remote facilities and critical applications requiring independence from electrical power.
- • Tier 4 compliant diesel engine
- • Automatic start system
- • Day tank fuel system
- • Remote monitoring capability
Jockey Pump System
Maintains system pressure and prevents unnecessary fire pump starts due to minor leaks. Essential component for automated fire protection systems.
- • Variable frequency drive control
- • Stainless steel construction
- • Automatic pressure control
- • Low maintenance design
Fire Pump Controller
Advanced microprocessor-based controllers providing reliable automatic and manual fire pump operation with comprehensive monitoring and alarm functions.
- • Digital display and controls
- • Remote monitoring interface
- • Event logging capability
- • Multiple alarm outputs
Fire Pump Room Package
Complete fire pump room solution including pumps, controllers, piping, valves, and accessories. Designed and assembled to meet all code requirements.
- • Engineered pump room layout
- • All required accessories
- • Code-compliant installation
- • Factory testing available
Accessories & Components
Essential fire pump accessories including pressure gauges, flow meters, check valves, pressure relief valves, and sensing lines for complete system integration.
- • Pressure relief valves
- • Check valves and strainers
- • Pressure gauges and sensors
- • Flexible connectors
Comprehensive Fire Pump Services
From installation to emergency repairs, we provide complete fire pump lifecycle support
Installation & Commissioning
- Site assessment and design
- Mechanical installation
- Electrical connections
- System commissioning
- Performance testing
Scheduled Maintenance
- Weekly inspection service
- Monthly operational tests
- Annual flow testing
- Controller maintenance
- Detailed reporting
24/7 Emergency Repair
- 24/7 hotline: 0917 158 5060
- 2-hour response time
- Emergency parts inventory
- Mobile service units
- Temporary pump rental
Inspection & Testing
- NFPA 25 compliance testing
- Annual performance tests
- BFP inspection support
- Detailed test reports
- Certification assistance
Repair & Overhaul
- Pump rebuild services
- Controller repairs
- Motor services
- Valve maintenance
- Parts replacement
Upgrades & Modernization
- Controller upgrades
- Remote monitoring systems
- Efficiency improvements
- Code compliance updates
- System integration
Fire Pump Operation Process
Understanding how your fire pump system works to protect your facility
1. Pressure Drop Detection
When a sprinkler activates, system pressure drops below the preset threshold (typically 5-10 PSI below normal operating pressure).
2. Automatic Start
Pressure switch signals the controller to automatically start the fire pump. Diesel pumps include automatic engine start sequence.
3. Water Flow
Fire pump draws water from the source and delivers it to the sprinkler system at the required pressure and flow rate.
4. Fire Suppression
Maintains adequate pressure and flow to all activated sprinklers until manually shut down after fire is extinguished.
Key Technical Specifications
Flow Rates
250 - 5000 GPM
Various capacities available to match system demand
Pressures
Up to 300 PSI
Single or multi-stage configurations
Operating Temperature
4°C to 40°C
Suitable for Philippine climate conditions
Frequently Asked Questions
Common questions about fire pump fire protection systems in the Philippines
What is a Fire Pump?
A fire pump is a specialized pump used in fire protection systems to provide high-pressure water for firefighting. Its main job is to make sure there’s enough water flow and pressure to feed fire sprinklers, standpipes, and other firefighting equipment—especially when the normal water supply can’t meet demand.
How much does a Fire Protection Fire Pump cost in the Philippines?
TheProjectEstimate.com lists a Horizontal Split Case Fire Pump (UL/FM-approved, 200 HP, 1000 GPM, with controller) at ₱3,599,876 per set, and a Jockey Pump at ₱568,326 while PinasHardware echoes that range: ₱3.6 million for a 200 HP main fire pump set.
Is a Fire Pump compliant with local Philippine regulations?
Yes — but only if it meets the Philippine Fire Code and related standards. In the Philippines, fire pumps are regulated under: The Fire Code of the Philippines (RA 9514), NFPA 20 – Standard for the Installation of Stationary Pumps for Fire Protection. A fire pump by itself isn’t “compliant” or “non-compliant” — compliance depends on: Approved design, Proper installation, and Successful BFP testing & inspection.
How often should fire pump be maintained?
In the Philippines, fire pumps must be maintained according to the Fire Code (RA 9514) and NFPA 25 standards to ensure reliability and compliance. This includes weekly run tests, monthly inspections, quarterly system checks, and an annual full-flow performance test, all recorded in a fire pump logbook. Proper maintenance not only prevents equipment failure during a fire but also ensures smooth Bureau of Fire Protection (BFP) inspections and certification renewals.
Do you provide emergency repair services for fire pump?
Yes, AA2000 offers 24/7 emergency response services for fire pump failures. Our certified technicians are available round-the-clock with rapid response times of 2-4 hours in Metro Manila and same-day service in major Philippine cities.