Fire Alarm PH Fire Alarm PH

Contact Us

      • Philippines
      • 09171585060

      aa2000ent@gmail.com

 

         

          • firealarmph.mayaritech,biz
          • Home
          • Services
            • Fire Protection System
              • STANDPIPE SYSTEM
              • FIRE PUMP
              • FIRE SPRINKLER
              • DELUGE SYSTEM
              • FOAM FIRE SUPPRESSION
              • KITCHEN FIRE SUPPRESSION
              • AEROSOL FIRE SUPPRESSION
              • WATER MIST SUPPRESSION
              • FIRE HYDRANT
              • FDAS FIRE ALARM
              • PORTABLE FIRE EXTINGUISHER
          • Products
            • Fire Detection Alarm System
              • EDWARDS*
              • NOTIFIER
              • SIMPLEX*
              • GAMEWELL BY HONEYWELL
              • ASENWARE
              • GST
              • TYY
              • HOCHIKI
              • HORING LIH
              • ESSER
              • BOSCH
              • COOPER
              • ORENA
              • HONEYWELL
          • BLOGS
          • Inquiry
          Fire Alarm PH Fire Alarm PH
          • Home
          • Services
            • Fire Protection System
              • STANDPIPE SYSTEM
              • FIRE PUMP
              • FIRE SPRINKLER
              • DELUGE SYSTEM
              • FOAM FIRE SUPPRESSION
              • KITCHEN FIRE SUPPRESSION
              • AEROSOL FIRE SUPPRESSION
              • WATER MIST SUPPRESSION
              • FIRE HYDRANT
              • FDAS FIRE ALARM
              • PORTABLE FIRE EXTINGUISHER
          • Products
            • Fire Detection Alarm System
              • EDWARDS*
              • NOTIFIER
              • SIMPLEX*
              • GAMEWELL BY HONEYWELL
              • ASENWARE
              • GST
              • TYY
              • HOCHIKI
              • HORING LIH
              • ESSER
              • BOSCH
              • COOPER
              • ORENA
              • HONEYWELL
          • BLOGS
          • Inquiry
          Fire Detection & Alarm Systems - AA2000 Philippines | Professional Fire Protection Solutions

          Professional Fire Detection & Alarm Systems

          Protect your business with cutting-edge fire detection technology. AA2000 provides comprehensive fire protection solutions including installation, maintenance, and 24/7 emergency support across the Philippines.

          BFP Compliant Edwards Authorized Dealer 25+ Years Experience 24/7 Emergency Support
          Fire Detection and Alarm System Components

          Complete FDAS Solutions

          From conventional to addressable systems, we provide end-to-end fire protection solutions tailored to your facility's needs.

          Comprehensive Fire Protection Services

          From initial consultation to emergency response, AA2000 provides complete fire detection and alarm system services across the Philippines

          System Installation

          Professional installation of fire detection and alarm systems with full BFP compliance documentation and certification.

          • • Site survey and system design
          • • BFP permit processing
          • • Professional installation
          • • System testing and commissioning

          Maintenance Services

          Regular preventive maintenance to ensure optimal system performance and BFP compliance requirements.

          • • Monthly system inspections
          • • Quarterly preventive maintenance
          • • Annual system certification
          • • Component replacement

          24/7 Emergency Support

          Round-the-clock emergency response for fire system failures, false alarms, and urgent repairs.

          • • 24/7 emergency hotline
          • • Rapid response technicians
          • • Emergency system bypass
          • • Immediate fault resolution

          Fire Detection System Components

          Understanding the key components of a comprehensive fire detection and alarm system

          Addressable Fire Alarm Control Panel

          Fire Alarm Control Panel (FACP)

          The brain of the fire detection system. Monitors all connected devices and provides centralized control and status indication.

          Features: LCD display, zone indication, silence/reset functions, battery backup, network connectivity
          Smoke Detection Devices

          Smoke Detectors

          Advanced photoelectric and ionization smoke detectors for early fire detection in various environments.

          Types: Photoelectric, ionization, dual-sensor, aspirating smoke detection systems
          Heat Detection Systems

          Heat Detectors

          Temperature-based fire detection ideal for areas where smoke detectors may cause false alarms.

          Types: Fixed temperature, rate-of-rise, combination heat detectors
          Manual Pull Stations

          Manual Pull Stations

          Manual fire alarm activation devices strategically placed throughout the facility for emergency activation.

          Features: Break glass design, weather-resistant, tamper-proof, dual-action models available
          Notification Devices Horn Strobe

          Notification Devices

          Horn-strobe combinations and speakers provide audible and visual emergency notifications.

          Options: Horn-strobes, speakers, LED strobes, voice evacuation systems
          FDAS System Integration

          System Integration

          Complete integration with building automation, elevator recall, HVAC shutdown, and emergency lighting systems.

          Integration: BMS connectivity, elevator recall, door release, HVAC control

          Fire Detection Process & Technology

          1

          Detection Phase

          Advanced sensors continuously monitor for smoke particles, heat changes, or flame signatures using photoelectric, ionization, or thermal detection technologies.

          2

          Signal Processing

          Intelligent algorithms analyze sensor data to differentiate between genuine fire conditions and potential false alarm sources like dust or steam.

          3

          Alarm Activation

          Upon confirmed fire detection, the system activates audible and visual alarms, initiates evacuation procedures, and sends alerts to monitoring stations.

          4

          System Integration

          Automatic activation of integrated systems including elevator recall, HVAC shutdown, door unlocking, and emergency lighting activation.

          5

          Emergency Response

          Immediate notification to fire department, building management, and our 24/7 monitoring center for rapid emergency response coordination.

          Fire Detection Process Diagram

          System Performance Metrics

          ≤30s
          Detection Response Time
          99.9%
          System Reliability
          24/7
          Monitoring Coverage
          BFP
          Compliant Systems

          BFP-Compliant Maintenance Schedule

          Comprehensive maintenance program ensuring optimal system performance and regulatory compliance

          Weekly Inspections

          • • Control panel status check
          • • Battery backup testing
          • • Visual device inspection
          • • Alarm log review

          Monthly Services

          • • Detector sensitivity testing
          • • Manual pull station testing
          • • Notification device testing
          • • System communication check

          Quarterly Maintenance

          • • Complete system testing
          • • Detector cleaning/calibration
          • • Battery replacement
          • • System performance analysis

          Annual Certification

          • • Full system commissioning
          • • BFP compliance certification
          • • System documentation update
          • • Performance report generation

          BFP Compliance Requirements

          Regulatory Standards

          • • Fire Code of the Philippines (RA 9514)
          • • National Fire Protection Association (NFPA) standards
          • • Philippine Electrical Code compliance
          • • Building Code of the Philippines integration
          • • Local government fire safety ordinances

          Required Documentation

          • • Fire Safety Evaluation Certificate (FSEC)
          • • System installation and testing records
          • • Maintenance and inspection logs
          • • Personnel training certificates
          • • Equipment certification documents

          Edwards Fire Detection Systems

          Authorized dealer of Edwards fire protection products with over 150 years of innovation

          Edwards EST4 Fire Alarm Control Panel

          The industry's most advanced fire alarm control platform with intelligent network architecture and full-color LCD touchscreen interface.

          • • Advanced network architecture with IPV6 support
          • • Large full-color LCD touch screen interface
          • • Flexible Class A, B, X, N or full mesh topology
          • • Compatible with fiber, Ethernet, and copper wiring
          • • UL Listed and FM Approved certification
          Edwards EST4 Control Panel

          Signature Series Detectors

          Advanced optical smoke detectors with enhanced sensitivity and false alarm immunity.

          • • SIGA-OSD Optical Smoke Detector
          • • SIGA-HRD Heat Detector
          • • SIGA-CT Combination Detector

          Manual Stations

          Intelligent manual pull stations with microprocessor technology.

          • • 279B-1110 Single Action Pull Station
          • • 279B-1120 Double Action Pull Station
          • • Weather-resistant outdoor models

          Notification Appliances

          Genesis LED horn-strobe combinations with high-efficiency LED technology.

          • • G4F Series Horn-Strobes
          • • Speaker-Strobe combinations
          • • Mass notification systems

          System Modules

          Input/output modules for comprehensive system integration.

          • • SIGA-CR Control Relay Module
          • • SIGA-IM Input Module
          • • SIGA-MIM Multi-Input Module

          24/7 Emergency Fire System Support

          Immediate response for fire system emergencies across the Philippines

          Emergency Hotline

          0917 158 5060

          Available 24/7 for immediate assistance

          Rapid Response

          2-Hour Response

          Emergency technicians deployed within 2 hours

          System Bypass

          Immediate Protection

          Temporary systems during repairs

          Common Emergency Situations We Handle

          System Failures

          • • Control panel malfunctions
          • • Detector failures
          • • Communication errors
          • • Power supply issues

          False Alarm Issues

          • • Detector contamination
          • • Environmental interference
          • • System sensitivity issues
          • • Wiring problems